Hydrant Digital Flow Meter

Features
- Zero reset at any time.
- Simultaneous reading of the PSI & LPM.
- Accountability system.
- Rechargeable battery with autonomy of 8 continuous hours.
- Two bright red LED screens 20mm X 8mm.
- Electronic components are sealed for protection against corrosion and condensation.
- Pressure measurement from 1.5 PSI.
- Continuous reading.
- Carrying handle.
Description
- Constructed of aluminium alloy with a black anodized finish for protection against corrosion.
- Electronic components are sealed for protection against corrosion and condensation.
- Can be used to measure flow, pressure, static pressure and the accountability of water usage.
Benefits
- Accurate
- Easy to use
- Multitude of flows
Portable Electronic Flowmeter
Construction
Anodized aluminium with PTFE finish. Electronic components are sealed for protection from the environment. No paddle wheel or Moving parts. Rechargeable 12 volt battery with 8 hour autonomy.
Technical Characteristics
- Compact and portable
- Two large, bright red, LED displays
- Instant calibration

Account
-ability |
Start from 0.1 Bar 11.5 PSI |
|
| |
Maximum possible 9999 X 1000 |
= 9999000 Litres |
| |
|
= 9999 M |
| |
|
= 9999000 GPM |
| Reading |
|
|
| Pressure |
Minimum: |
0.1 Bar/ 1.5 PSI |
| |
Maximum: |
18 Bars / 260 PSI |
| |
Accuracy: |
+ 0.05 Bar/+ 0.7 P.S.I. |
| Description |
Code |
| British Instantaneous 2.5" (65mm) male and female |
8165 |
| Inlet and Outlet Storz C/52mm |
8166 |
| Inlet and Outlet Storz DN 65mm |
8167 |
| Inlet and Outlet Storz DN 100mm |
8168 |
| Inlet and Outlet Storz DN 150mm |
8170 |
| OPTIONS: |
|
| DN 65 - 2.5" Calibration kit for NF hydrant |
8174 |
| DN 100 - 4.0" Calibration kit for NF hydrant |
8175 |
| Supervisor transfer software RS 232 |
13203 |
Options Available
- High pressure unit above 18 Bars 1260 PSI.
- High volume unit above the regular flow
- PC connecting cables
- Transfer software from the flowmeter directly To a PC.
- Reading pressure BAR, flow rate CPM.
- Nozzle tips adapter to alter inlet dimensional Reading sizes from flowmeter
Set-up is Fast & Easy
- The flowmeter shall be of the same dimension of what you intend to flow on both the inlet and the outlet.
NOTE: Nozzle tips adapter to alter inlet
Dimensional reading sizes are available.
- Ensure that the flowmeter is fully charged.
- Make all the proper connection and attachment to your flowmeter and ensure that the flow arrow of the flowmeter is in the proper direction.
- Turn the flowmeter ON.
- Depress the "CAL" for calibration.
- Open the water supply very slowly to minimize "Water hammer" and initial turbulence into the Flowmeter.
- Read your reading from the PSI and LPM Windows.
NOTE: If at any time the "CAL" is depressed by Accident while reading, the flowmeter will fall in a calibration mode at the existing pressure and GPM fl owing at the moment. Simply shut down your water supply and turn the flowmeter "OFF" And "ON" again, depress "CAL" and re-open your Water supply.
|